源码网商城,靠谱的源码在线交易网站 我的订单 购物车 帮助

源码网商城

VBS 硬盘读写统计(分区读写统计)

  • 时间:2022-07-10 02:02 编辑: 来源: 阅读:
  • 扫一扫,手机访问
摘要:VBS 硬盘读写统计(分区读写统计)
WinXP,Win7,Win8
[u]复制代码[/u] 代码如下:
'原创内容转载、引用代码核心部分请注明出处 硬盘读写统计.vbs If (Lcase(Right(Wscript.FullName,11)) = "wscript.exe") Then    CreateObject("WScript.Shell").Run("%Comspec% /C " &Chr(34)&"mode con cols=52 lines=22" &"&Title  硬盘读写统计.vbs  By: FastSLZ  PCEVA Or BatHome   &&Cscript.exe //NoLogo  "&Chr(34)& Wscript.ScriptFullName &Chr(34)&Chr(34)),3:Set WMI = Nothing:Wscript.Quit End If Dim WMI,vName,IDE,cPPP,sNow Input = 1:InputS = Input*980 On Error Resume Next Set WMI = GetObject("winmgmts:{impersonationLevel=impersonate}!\\.\root\cimv2") Set IDE = WMI.ExecQuery("Select * from Win32_DiskDrive WHERE InterfaceType='IDE'") Set cPPP = WMI.ExecQuery("SELECT * FROM Win32_PerfRawData_PerfDisk_PhysicalDisk WHERE Name <> '_Total'") For Each oIDE In IDE     For i = 0 To IDE.Count           Select Case oIDE.Index             Case i                For Each oPPP In cPPP                    If InStr(oPPP.Name, i) Then vName = oPPP.Name                Next                Select Case i                    Case 0 Disk0=oIDE.Caption&" "&oIDE.FirmwareRevision:Size0=oIDE.Size:DskP0=vName                    Case 1 Disk1=oIDE.Caption&" "&oIDE.FirmwareRevision:Size1=oIDE.Size:DskP1=vName                    Case 2 Disk2=oIDE.Caption&" "&oIDE.FirmwareRevision:Size2=oIDE.Size:DskP2=vName                    Case 3 Disk3=oIDE.Caption&" "&oIDE.FirmwareRevision:Size3=oIDE.Size:DskP3=vName                    Case 4 Disk4=oIDE.Caption&" "&oIDE.FirmwareRevision:Size4=oIDE.Size:DskP4=vName                    Case 5 Disk5=oIDE.Caption&" "&oIDE.FirmwareRevision:Size5=oIDE.Size:DskP5=vName                End Select         End Select     Next Next Set cPPP = Nothing:Set IDE= Nothing If Disk0 <> "" Then WScript.Echo Left(DskP0,1)&":"&vbTab& Disk0 &vbTab _                   &vbCrLf&vbTab&"厂商容量:"&Round(Size0/1000000000) &"GB" _                   &vbCrLf&vbTab&"实际容量:"&Round(Size0/1073741824,2) &"GB" _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP0,Len(DskP0)-2) If Disk1 <> "" Then WScript.Echo Left(DskP1,1)&":"&vbTab& Disk1 &vbTab _                   &vbCrLf&vbTab&"厂商容量:"&Round(Size1/1000000000) &"GB" _                   &vbCrLf&vbTab&"实际容量:"&Round(Size1/1073741824,2) &"GB" _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP1,Len(DskP1)-2) If Disk2 <> "" Then WScript.Echo Left(DskP2,1)&":"&vbTab& Disk2 &vbTab _                   &vbCrLf&vbTab&"厂商容量:"&Round(Size2/1000000000) &"GB" _                   &vbCrLf&vbTab&"实际容量:"&Round(Size2/1073741824,2) &"GB" _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP2,Len(DskP2)-2) If Disk3 <> "" Then WScript.Echo Left(DskP3,1)&":"&vbTab& Disk3 &vbTab _                   &vbCrLf&vbTab&"厂商容量:"&Round(Size3/1000000000) &"GB" _                   &vbCrLf&vbTab&"实际容量:"&Round(Size3/1073741824,2) &"GB" _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP3,Len(DskP3)-2) If Disk4 <> "" Then WScript.Echo Left(DskP4,1)&":"&vbTab& Disk4 &vbTab _                   &vbCrLf&vbTab&"厂商容量:"&Round(Size4/1000000000) &"GB" _                   &vbCrLf&vbTab&"实际容量:"&Round(Size4/1073741824,2) &"GB" _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP4,Len(DskP4)-2) If Disk5 <> "" Then WScript.Echo Left(DskP5,1)&":"&vbTab& Disk5 &vbTab _                   &vbCrLf&vbTab&"厂商容量:"&Round(Size5/1000000000) &"GB" _                   &vbCrLf&vbTab&"实际容量:"&Round(Size5/1073741824,2) &"GB" _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP5,Len(DskP5)-2) WScript.Echo "↑请输入要监控的硬盘编号,并按回车键" stdInput = WScript.StdIn.Readline stdInput=Left(UCase(stdInput),1) If stdInput > "5" Or stdInput < "0" Then MsgBox "输入错误" :WScript.Quit If InStr(DskP0, stdInput) Then Call Network(Disk0,Size0,DskP0) If InStr(DskP1, stdInput) Then Call Network(Disk1,Size1,DskP1) If InStr(DskP2, stdInput) Then Call Network(Disk2,Size2,DskP2) If InStr(DskP3, stdInput) Then Call Network(Disk3,Size3,DskP3) If InStr(DskP4, stdInput) Then Call Network(Disk4,Size4,DskP4) If InStr(DskP5, stdInput) Then Call Network(Disk5,Size5,DskP5) Sub Network(Disks,Sizes,DskPs) sNow=Now Do Dim A 'WScript.Echo "已运行"&Ts\3600&"小时"&(Ts mod 3600)\60&"分钟"&(Ts mod 3600) mod 60&"秒" Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_PhysicalDisk Where Name='"&DskPs&"'") For Each B In A     R1 = B.DiskReadBytesPersec     W1 = B.DiskWriteBytesPersec     If RA0 = "" Then RA0 = B.DiskReadBytesPersec Else RA1 = R1 End If     If WA0 = "" Then WA0 = B.DiskWriteBytesPersec Else WA1 = W1 End If Next Set A = Nothing WScript.Sleep(InputS) Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_PhysicalDisk Where Name='"&DskPs&"'") For Each B In A     R2 = B.DiskReadBytesPersec     W2 = B.DiskWriteBytesPersec Next Set A = Nothing WScript.Echo Disks &" " &Round(Sizes/1073741824) &"GB" &vbCrLf _       &"实时读取:" & CheckSize((R2-R1)/Input) &"/s" &vbCrLf _       &"实时写人:" & CheckSize((W2-W1)/Input) &"/s"&vbCrLf _       &"脚本累计读取:" & CheckSize(RA1-RA0) &vbCrLf _       &"脚本累计写入:" & CheckSize(WA1-WA0) &vbCrLf _       &"开机累计读取:" & CheckSize(R1) &vbCrLf _       &"开机累计写入:" & CheckSize(W1) &vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf _       &"已运行"&Ts\3600&"小时"&(Ts mod 3600)\60&"分钟"&(Ts mod 3600) mod 60&"秒" Ts=DateDiff("s", sNow, Now)'Ts=TS+1 Loop End Sub Function CheckSize(SZ) On Error Resume Next If SZ => 1073741824 Then    SZ = FormatNumber(Round(SZ/1073741824,2))&" GB"    ElseIf SZ => 1048576 Then    SZ = FormatNumber(Round(SZ/1048576,2))&" MB"    ElseIf SZ => 1024 Then    SZ = FormatNumber(Round(SZ/1024,2))&" KB" Else    SZ = "0"&FormatNumber(Round(SZ/1024,2)) & " KB" End If CheckSize=Right("      " & SZ,10) End Function
分区读写统计.vbs
[u]复制代码[/u] 代码如下:
'原创内容转载、引用代码核心部分请注明出处 If (Lcase(Right(Wscript.FullName,11)) = "wscript.exe") Then    CreateObject("WScript.Shell").Run("%Comspec% /C " &Chr(34)&"mode con cols=52 lines=22" &"&Title  分区读写统计.vbs  By: FastSLZ  PCEVA Or BatHome   &&Cscript.exe //NoLogo  "&Chr(34)& Wscript.ScriptFullName &Chr(34)&Chr(34)),3:Set WMI = Nothing:Wscript.Quit End If Input = 1:InputS = Input*1000 Dim WMI,vName,IDE,cPPP,sNow On Error Resume Next Set WMI = GetObject("winmgmts:{impersonationLevel=impersonate}!\\.\root\cimv2") Set IDE = WMI.ExecQuery("Select * from Win32_DiskDrive WHERE InterfaceType='IDE'") Set cPPP = WMI.ExecQuery("SELECT * FROM Win32_PerfRawData_PerfDisk_PhysicalDisk WHERE Name<>'_Total'") For Each oIDE In IDE     For i = 0 To IDE.Count           Select Case oIDE.Index             Case i                For Each oPPP In cPPP                    If InStr(oPPP.Name, i) Then vName = oPPP.Name                Next                Select Case i                    Case 0 Disk0=oIDE.Caption&" "&oIDE.FirmwareRevision:Size0=oIDE.Size:DskP0=vName                    Case 1 Disk1=oIDE.Caption&" "&oIDE.FirmwareRevision:Size1=oIDE.Size:DskP1=vName                    Case 2 Disk2=oIDE.Caption&" "&oIDE.FirmwareRevision:Size2=oIDE.Size:DskP2=vName                    Case 3 Disk3=oIDE.Caption&" "&oIDE.FirmwareRevision:Size3=oIDE.Size:DskP3=vName                    Case 4 Disk4=oIDE.Caption&" "&oIDE.FirmwareRevision:Size4=oIDE.Size:DskP4=vName                    Case 5 Disk5=oIDE.Caption&" "&oIDE.FirmwareRevision:Size5=oIDE.Size:DskP5=vName                End Select         End Select     Next Next Set cPPP = Nothing:Set IDE= Nothing If Disk0 <> "" Then DskP=Right(DskP0,Len(DskP0)-2):WScript.Echo Left(DskP0,1)&":"&vbTab& Disk0 &vbTab _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP0,Len(DskP0)-2) If Disk1 <> "" Then DskP=DskP&" "&Right(DskP1,Len(DskP1)-2):WScript.Echo Left(DskP1,1)&":"&vbTab& Disk1 &vbTab _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP1,Len(DskP1)-2) If Disk2 <> "" Then DskP=DskP&" "&Right(DskP2,Len(DskP2)-2):WScript.Echo Left(DskP2,1)&":"&vbTab& Disk2 &vbTab _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP2,Len(DskP2)-2) If Disk3 <> "" Then DskP=DskP&" "&Right(DskP3,Len(DskP3)-2):WScript.Echo Left(DskP3,1)&":"&vbTab& Disk3 &vbTab _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP3,Len(DskP3)-2) If Disk4 <> "" Then DskP=DskP&" "&Right(DskP4,Len(DskP4)-2):WScript.Echo Left(DskP4,1)&":"&vbTab& Disk4 &vbTab _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP4,Len(DskP4)-2) If Disk5 <> "" Then DskP=DskP&" "&Right(DskP5,Len(DskP5)-2):WScript.Echo Left(DskP5,1)&":"&vbTab& Disk5 &vbTab _                   &vbCrLf&vbTab&"分区状态:"&Right(DskP5,Len(DskP5)-2) WScript.Echo vbCrLf&"请输入"&DskP&"中任意一个盘符" stdInput = WScript.StdIn.Readline stdInput=Left(UCase(stdInput),1) If InStr(DskP,stdInput) Then Call Network(stdInput&":") Sub Network(DskPs) sNow=Now Do Dim A Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_LogicalDisk Where Name = '"& DskPs &"'") For Each B In A     R1 = B.DiskReadBytesPersec     W1 = B.DiskWriteBytesPersec     If RA0 = "" Then RA0 = B.DiskReadBytesPersec Else RA1 = R1 End If     If WA0 = "" Then WA0 = B.DiskWriteBytesPersec Else WA1 = W1 End If Next Set A = Nothing WScript.Sleep(InputS) Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_LogicalDisk Where Name = '"& DskPs &"'") For Each B In A     R2 = B.DiskReadBytesPersec     W2 = B.DiskWriteBytesPersec Next Set A = Nothing WScript.Echo "监控分区:" &DskPs &vbCrLf _       &"实时读取:" & CheckSize((R2-R1)/Input) &"/s" &vbCrLf _       &"实时写人:" & CheckSize((W2-W1)/Input) &"/s"&vbCrLf _       &"脚本累计读取:" & CheckSize(RA1-RA0) &vbCrLf _       &"脚本累计写入:" & CheckSize(WA1-WA0) &vbCrLf _       &"开机累计读取:" & CheckSize(R1) &vbCrLf _       &"开机累计写入:" & CheckSize(W1) &vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf _       &"已运行"&Ts\3600&"小时"&(Ts mod 3600)\60&"分钟"&(Ts mod 3600) mod 60&"秒" Ts=DateDiff("s", sNow, Now)'Ts=TS+1 Loop End Sub Function CheckSize(SZ) On Error Resume Next If SZ => 1073741824 Then    SZ = FormatNumber(Round(SZ/1073741824,2))&" GB"    ElseIf SZ => 1048576 Then    SZ = FormatNumber(Round(SZ/1048576,2))&" MB"    ElseIf SZ => 1024 Then    SZ = FormatNumber(Round(SZ/1024,2))&" KB" Else    SZ = "0"&FormatNumber(Round(SZ/1024,2)) & " KB" End If CheckSize=Right("      " & SZ,10) End Function
  • 全部评论(0)
联系客服
客服电话:
400-000-3129
微信版

扫一扫进微信版
返回顶部